0
0
Cart
Your shopping cart is empty!
It's never too late to make things right :)

Engine-Powered Generators: Petrol, Diesel, Gas and Inverter Models

Top
Gasoline generator 7.2/8 kW HUTER DY9500LX
Gasoline generator 7.2/8 kW HUTER DY9500LX Gasoline generator 7.2/8 kW HUTER DY9500LX Gasoline generator 7.2/8 kW HUTER DY9500LX Gasoline generator 7.2/8 kW HUTER DY9500LX Gasoline generator 7.2/8 kW HUTER DY9500LX Gasoline generator 7.2/8 kW HUTER DY9500LX
Model: DY9500LX
In stock
476,160֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Open
New
Top
TSS SGG 5000N 5.5 kW gasoline generator with 25 L tank
TSS SGG 5000N 5.5 kW gasoline generator with 25 L tank TSS SGG 5000N 5.5 kW gasoline generator with 25 L tank TSS SGG 5000N 5.5 kW gasoline generator with 25 L tank TSS SGG 5000N 5.5 kW gasoline generator with 25 L tank TSS SGG 5000N 5.5 kW gasoline generator with 25 L tank
Model: SGG 5000N
In stock
477,360֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Open
New
Top
BRAIT BR5000i 3.7 kW inverter generator with casing
BRAIT BR5000i 3.7 kW inverter generator with casing BRAIT BR5000i 3.7 kW inverter generator with casing BRAIT BR5000i 3.7 kW inverter generator with casing BRAIT BR5000i 3.7 kW inverter generator with casing
Model: BR5000i
In stock
483,600֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Closed sound-insulated
Top
Gasoline generator 5/5.5 kW HUTER DY6500LXA
Gasoline generator 5/5.5 kW HUTER DY6500LXA Gasoline generator 5/5.5 kW HUTER DY6500LXA Gasoline generator 5/5.5 kW HUTER DY6500LXA Gasoline generator 5/5.5 kW HUTER DY6500LXA Gasoline generator 5/5.5 kW HUTER DY6500LXA Gasoline generator 5/5.5 kW HUTER DY6500LXA
Model: DY6500LXA
In stock
489,600֏
Automatic Transfer Switch (ATS): Yes
Certificate of Conformity number:
ATS connector: Yes
Casing type: Open
New
Top
TSS SGG 5000EHNA 5.5 kW gasoline generator with ATS connector
TSS SGG 5000EHNA 5.5 kW gasoline generator with ATS connector TSS SGG 5000EHNA 5.5 kW gasoline generator with ATS connector TSS SGG 5000EHNA 5.5 kW gasoline generator with ATS connector TSS SGG 5000EHNA 5.5 kW gasoline generator with ATS connector TSS SGG 5000EHNA 5.5 kW gasoline generator with ATS connector
Model: SGG 5000EHNA
In stock
489,600֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: Yes
Casing type: Open
New
Top
TSS SGG 3000ESi 3 kW inverter generator with casing
TSS SGG 3000ESi 3 kW inverter generator with casing TSS SGG 3000ESi 3 kW inverter generator with casing TSS SGG 3000ESi 3 kW inverter generator with casing TSS SGG 3000ESi 3 kW inverter generator with casing
Model: SGG 3000ESi
In stock
492,960֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Closed sound-insulated
New
Top
BRAIT BR7500iOMPRO 5.5 kW inverter generator with open frame
BRAIT BR7500iOMPRO 5.5 kW inverter generator with open frame BRAIT BR7500iOMPRO 5.5 kW inverter generator with open frame BRAIT BR7500iOMPRO 5.5 kW inverter generator with open frame BRAIT BR7500iOMPRO 5.5 kW inverter generator with open frame BRAIT BR7500iOMPRO 5.5 kW inverter generator with open frame BRAIT BR7500iOMPRO 5.5 kW inverter generator with open frame
Model: BR7500iOMPRO
In stock
499,200֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Open
New
Top
FUBAG BS 6600 6.6 kW gasoline generator
FUBAG BS 6600 6.6 kW gasoline generator FUBAG BS 6600 6.6 kW gasoline generator FUBAG BS 6600 6.6 kW gasoline generator
Model: BS 6600
In stock
505,440֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Open
New
Top
EMTOP EGGRD7511 7.5 kW single-phase gasoline generator with electric start
EMTOP EGGRD7511 7.5 kW single-phase gasoline generator with electric start EMTOP EGGRD7511 7.5 kW single-phase gasoline generator with electric start EMTOP EGGRD7511 7.5 kW single-phase gasoline generator with electric start
Model: EGGRD7511
In stock
512,640֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Open
New
Top
BRAIT GB-5500S PRO 5.5 kW gasoline generator
BRAIT GB-5500S PRO 5.5 kW gasoline generator BRAIT GB-5500S PRO 5.5 kW gasoline generator BRAIT GB-5500S PRO 5.5 kW gasoline generator BRAIT GB-5500S PRO 5.5 kW gasoline generator
Model: GB-5500S PRO
In stock
513,240֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Open
New
Top
BRAIT BR-6500CU(E) 6.5 kW gasoline generator with electric start
BRAIT BR-6500CU(E) 6.5 kW gasoline generator with electric start BRAIT BR-6500CU(E) 6.5 kW gasoline generator with electric start BRAIT BR-6500CU(E) 6.5 kW gasoline generator with electric start BRAIT BR-6500CU(E) 6.5 kW gasoline generator with electric start
Model: BR-6500CU(Е)
In stock
514,800֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Open
New
Top
BRAIT BR6500-CU(E) 6.5 kW gasoline generator with electric start
BRAIT BR6500-CU(E) 6.5 kW gasoline generator with electric start BRAIT BR6500-CU(E) 6.5 kW gasoline generator with electric start BRAIT BR6500-CU(E) 6.5 kW gasoline generator with electric start BRAIT BR6500-CU(E) 6.5 kW gasoline generator with electric start
Model: BR6500-CU(E)
In stock
514,800֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Open
New
Top
TOTAL TP430001 3 kW single-phase open-frame diesel generator
TOTAL TP430001 3 kW single-phase open-frame diesel generator TOTAL TP430001 3 kW single-phase open-frame diesel generator TOTAL TP430001 3 kW single-phase open-frame diesel generator
Model: TP430001
In stock
521,280֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Open
New
Top
DYLLU DTGEAB10 7.5 kW inverter gasoline generator with electric start
Model: DTGEAB10
In stock
524,133֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: No
Casing type: Open
New
Top
BRAIT GB-5500E PRO 5.5 kW gasoline generator with electric start
BRAIT GB-5500E PRO 5.5 kW gasoline generator with electric start BRAIT GB-5500E PRO 5.5 kW gasoline generator with electric start BRAIT GB-5500E PRO 5.5 kW gasoline generator with electric start BRAIT GB-5500E PRO 5.5 kW gasoline generator with electric start
Model: GB-5500Е PRO
In stock
530,400֏
Automatic Transfer Switch (ATS): No
Certificate of Conformity number:
ATS connector: Yes
Casing type: Open

Engine-Powered Generators: Petrol, Diesel, Gas and Inverter Models

Engine-Powered Generators

A detailed buying guide: how to choose a gasoline generator.

This section covers internal-combustion engine generators: petrol, diesel, gas (LPG) and dual-fuel, as well as inverter models. They provide off-grid or backup power for homes, country houses, shops, small workshops and construction sites, as well as for camping and field work. The category ranges from 1–3 kW portable units to 10–30 kVA three-phase sets. For choosing one for your home, read how to choose a generator for home use.

What to consider when choosing an engine-powered generator

Fuel type: petrol, diesel, gas or dual-fuel

Petrol generators are light and affordable and suit occasional, short-term use, while diesel units are economical, durable and built for long, continuous loads. Gas and dual-fuel (petrol/LPG) models run on bottled or mains gas, burn cleaner and cut fuel costs. See how to choose a diesel generator and differences between two-stroke, four-stroke and diesel engines.

Rated and maximum power

Choose by rated (continuous) power, not the maximum the generator delivers only briefly. Add up the power of all loads, allow for the 2–3 times higher starting current of motor-driven appliances (pump, compressor, refrigerator) and keep a 20–30% margin; to convert kVA to kW, multiply by 0.8. Read how to calculate required generator power.

Inverter or conventional generator

Inverter generators deliver stable voltage and a pure sine wave, so they are safe for computers, TVs, boiler controls and other electronics, and at light loads they automatically lower engine speed to save fuel. Conventional (synchronous or asynchronous) generators are simpler and suit tools, lighting and heaters. See how to choose an inverter generator.

Single-phase 220 V or three-phase 380 V

A single-phase 220 V generator is enough for a home and most construction tools, while three-phase 380 V models are needed for three-phase motors, concrete mixers and production equipment. On a three-phase generator, spread the load evenly across the phases. Read differences between single-phase and three-phase generators and how to choose a generator for a construction site.

Starting and automatic start

A recoil starter is enough for small portable models, while electric start and remote start are convenient on generators above 5 kW and on diesel units. For backup power, choose a model that can connect to an ATS (automatic transfer switch) panel so that it starts automatically when the mains fails.

Tank, runtime and consumption

Tank capacity and consumption (l/h at 50–75% load) determine how many hours the generator runs without refuelling, usually 8–15 hours. Diesel and inverter models use less fuel per kWh, while the runtime of gas models depends on the cylinder size. Read fuel, engine oil and two-stroke mix: how to choose and use them correctly.

Noise and enclosure

Open-frame generators usually produce 70–80 dB at 7 m, while models in a soundproof (silent) enclosure and inverter units produce 52–68 dB. For residential areas and night use, choose an enclosed model; on a construction site, an open frame makes servicing easier. See what is noise level in db.

AVR, protection and outlets

An automatic voltage regulator (AVR) keeps voltage within safe limits, while a circuit breaker and overload and low-oil protection safeguard the generator and connected appliances. Check the number and type of 220 V and 380 V outlets, a 12 V output, the hour meter and the voltage and current display.

Safety, grounding and maintenance

Place the generator only outdoors or in a well-ventilated spot away from windows, since the exhaust contains carbon monoxide; ground the frame and connect it to the house wiring only through a changeover switch or ATS. Change the oil every 50–100 engine hours, clean the air filter and run a standby generator periodically. Read how to use a generator safely, how to choose grounding and lightning protection equipment and how to store and maintain a generator.

At ToolsArmenia you can compare engine-powered generators by fuel type, rated power, number of phases, inverter technology, starting system and noise level and choose the right model for your home or site.

icon_viber icon_teleg icon_callback icon_email icon_mes icon_skype