How to Calculate the Required Heater Output by Volume, Temperature and Insulation

ToolsArmenia Knowledge Base

How to Calculate the Required Heater Output by Volume, Temperature and Insulation

A heater that is too weak will not warm the space, while one that is too powerful overloads the supply and wastes money. Below are two ways to calculate: a quick one (by floor area) and an accurate one (by volume), with simple examples.

Reading time: about 7 min Updated: November 2026 ToolsArmenia Editorial Team

What “required heater output” means

The required output is the amount of heat (kW) that must be supplied continuously to make up for losses through walls, windows, ceiling and ventilation and to hold the desired temperature.

It depends on three things: the room volume, the difference between indoor and outdoor temperature, and the building insulation. For an electric heater heat output and electrical power are almost equal, so the result can be compared directly with the rating of an electric heater.

Important

The calculation gives the minimum output. Add a 10–20% margin so the heater does not have to run flat out all the time.

Calculation methods

Quick method: by floor area

For a normally insulated room with a 2.5–2.7 m ceiling, allow 1 kW for every 10 m². A 25 m² room needs about 2.5 kW. This method ignores high ceilings and poor insulation.

Accurate method: by volume

Formula: P (kW) = V × ΔT × K ÷ 860, where V is the volume (m³), ΔT is the indoor–outdoor temperature difference (°C), K is the insulation factor, and 860 converts kcal/h into kW.

Insulation factor K

K ≈ 0.6–0.9: well-insulated building, modern windows. K ≈ 1.0–1.9: ordinary insulation, double brickwork. K ≈ 2.0–2.9: poor insulation, simple walls. K ≈ 3.0–4.0: almost no insulation, metal warehouse, building site.

Temperature difference

ΔT = desired indoor temperature − minimum outdoor temperature. If you need +18 °C inside and it is −7 °C outside, ΔT = 25 °C. For drying on a site +10…+15 °C is often enough.

Example

Garage 6 × 4 × 2.8 m = 67 m³, ΔT = 20 °C, poor insulation K = 2.5. P = 67 × 20 × 2.5 ÷ 860 ≈ 3.9 kW. A 5 kW electric heat gun fits, or a fuel-fired space heater if there is no 380 V.

Warning

If the result is above 5 kW, check that the supply can handle the load. Connecting a powerful heater to a weak line can overheat the cable and trip the breaker.

Comparing options

Approximate output for a room with a 2.7 m ceiling at ΔT ≈ 20 °C.

Floor areaGood insulationOrdinary insulationPoor insulation
10 m²0.6–0.8 kW1–1.5 kW1.5–2 kW
20 m²1.2–1.6 kW2–3 kW3–4 kW
40 m²2.5–3 kW4–5 kW6–8 kW
100 m²6–8 kW10–12 kW15–20 kW

Common mistakes

  • Calculating by floor area only when the ceiling is higher than 3 m.
  • Forgetting the minimum outdoor temperature and sizing for a mild day.
  • Using a good-insulation factor for a metal warehouse.
  • Choosing a heater exactly at the calculated value with no margin.
  • Not checking whether the supply can carry the chosen output.

Good practice

For large, poorly insulated spaces compare running costs with a gas or diesel heater: above 15–20 kW fuel-fired heating is often more realistic.

Final checklist

  • I have measured the length, width and height of the room
  • I have set the desired indoor and minimum outdoor temperature
  • I have chosen the insulation factor
  • I have calculated the output with the formula
  • I have added a 10–20% margin
  • I have checked that the supply can carry this output

Frequently asked questions

How many kW does a 30 m² home need

With ordinary insulation and a 2.7 m ceiling, about 3 kW. In a cold winter or with poor insulation, 4–4.5 kW.

Why do the area and volume methods give different results

The area method assumes a standard ceiling and average insulation. The volume method uses the real height, temperatures and insulation.

What does 860 in the formula mean

It converts kcal/h into kW: 1 kW ≈ 860 kcal/h.

Can I use two small heaters instead of one big one

Yes, it even gives more even heat. Just plug them into different sockets and check that the circuit can carry the total load.

How much does an electric heater consume

In one hour it uses energy equal to its rating: a 2 kW heater uses 2 kWh. A thermostat reduces the actual running time.

Prepared by the ToolsArmenia Editorial Team. Correctly calculated output gives warmth without overloading the supply or wasting money.