ToolsArmenia Knowledge Base How to Calculate the Required Heater Output by Volume, Temperature and Insulation A heater that is too weak will not warm the space, while one that is too powerful overloads the supply and wastes money. Below are two ways to calculate: a quick one (by floor area) and an accurate one (by volume), with simple examples. Reading time: about 7 min Updated: November 2026 ToolsArmenia Editorial Team Contents What “required heater output” meansCalculation methodsComparing optionsCommon mistakesFinal checklistFAQ What “required heater output” meansThe required output is the amount of heat (kW) that must be supplied continuously to make up for losses through walls, windows, ceiling and ventilation and to hold the desired temperature.It depends on three things: the room volume, the difference between indoor and outdoor temperature, and the building insulation. For an electric heater heat output and electrical power are almost equal, so the result can be compared directly with the rating of an electric heater.ImportantThe calculation gives the minimum output. Add a 10–20% margin so the heater does not have to run flat out all the time. Calculation methodsQuick method: by floor areaFor a normally insulated room with a 2.5–2.7 m ceiling, allow 1 kW for every 10 m². A 25 m² room needs about 2.5 kW. This method ignores high ceilings and poor insulation.Accurate method: by volumeFormula: P (kW) = V × ΔT × K ÷ 860, where V is the volume (m³), ΔT is the indoor–outdoor temperature difference (°C), K is the insulation factor, and 860 converts kcal/h into kW.Insulation factor KK ≈ 0.6–0.9: well-insulated building, modern windows. K ≈ 1.0–1.9: ordinary insulation, double brickwork. K ≈ 2.0–2.9: poor insulation, simple walls. K ≈ 3.0–4.0: almost no insulation, metal warehouse, building site.Temperature differenceΔT = desired indoor temperature − minimum outdoor temperature. If you need +18 °C inside and it is −7 °C outside, ΔT = 25 °C. For drying on a site +10…+15 °C is often enough.ExampleGarage 6 × 4 × 2.8 m = 67 m³, ΔT = 20 °C, poor insulation K = 2.5. P = 67 × 20 × 2.5 ÷ 860 ≈ 3.9 kW. A 5 kW electric heat gun fits, or a fuel-fired space heater if there is no 380 V.WarningIf the result is above 5 kW, check that the supply can handle the load. Connecting a powerful heater to a weak line can overheat the cable and trip the breaker. Comparing optionsApproximate output for a room with a 2.7 m ceiling at ΔT ≈ 20 °C.Floor areaGood insulationOrdinary insulationPoor insulation10 m²0.6–0.8 kW1–1.5 kW1.5–2 kW20 m²1.2–1.6 kW2–3 kW3–4 kW40 m²2.5–3 kW4–5 kW6–8 kW100 m²6–8 kW10–12 kW15–20 kW Common mistakesCalculating by floor area only when the ceiling is higher than 3 m.Forgetting the minimum outdoor temperature and sizing for a mild day.Using a good-insulation factor for a metal warehouse.Choosing a heater exactly at the calculated value with no margin.Not checking whether the supply can carry the chosen output.Good practiceFor large, poorly insulated spaces compare running costs with a gas or diesel heater: above 15–20 kW fuel-fired heating is often more realistic. Final checklistI have measured the length, width and height of the roomI have set the desired indoor and minimum outdoor temperatureI have chosen the insulation factorI have calculated the output with the formulaI have added a 10–20% marginI have checked that the supply can carry this output Frequently asked questionsHow many kW does a 30 m² home needWith ordinary insulation and a 2.7 m ceiling, about 3 kW. In a cold winter or with poor insulation, 4–4.5 kW.Why do the area and volume methods give different resultsThe area method assumes a standard ceiling and average insulation. The volume method uses the real height, temperatures and insulation.What does 860 in the formula meanIt converts kcal/h into kW: 1 kW ≈ 860 kcal/h.Can I use two small heaters instead of one big oneYes, it even gives more even heat. Just plug them into different sockets and check that the circuit can carry the total load.How much does an electric heater consumeIn one hour it uses energy equal to its rating: a 2 kW heater uses 2 kWh. A thermostat reduces the actual running time. Read alsohow to choose an electric space heater or heat blowerelectric heater types and heating elementshow to choose a gas or diesel heaterhow to use an extension cord safely Related categoriesElectric space heatersElectric heat gunsGas and diesel space heaters Next article: electric heater types and heating elements